Skip to content

4.6 Bouwfysische eigenschappen — NLRS_C_ZTA_min >=0

{
  "Id": "9612d483-d3e8-4580-bdce-b10f36ed2932",
  "Filter": {
    "Type": "filterCollection",
    "Properties": [
      {
        "Name": "Operator",
        "Value": "and",
        "Type": null
      }
    ],
    "SubFilters": [
      {
        "Type": "familySymbolFilter",
        "Properties": [],
        "SubFilters": []
      },
      {
        "Type": "queryFilter",
        "Properties": [
          {
            "Name": "Query",
            "Value": "$[$string(values.assemblyCode) ~> /^31\\.(1[012]|2[012345]|3[01234]|4[01])$/i]",
            "Type": null
          }
        ],
        "SubFilters": []
      }
    ]
  },
  "Validation": {
    "Type": "validation",
    "Name": "NLRS_C_ZTA_min >=0",
    "ErrorMessage": "#### Issue\n\nDe parameter **NLRS_C_ZTA_min** is niet ingevuld voor dit element.\n\nDeze parameter is vereist voor bouwdelen waarvoor eisen gelden aan **contactgeluidisolatie** .\n\n#### Oplossing\n\nVul een geldige waarde in voor de parameter **NLRS_C_ZTA_min** :\n\n- Controleer of het element een **scheidende constructie** betreft\n- Vul de waarde in als **typeparameter** , conform de geldende project- of contractspecificaties\n\n#### Informatie\n\nVolgens de **BIM Basis ILS – §4.6 Bouwfysische eigenschappen**  moeten scheidende bouwdelen met relevante **Assembly Codes (31.\\*)**  voorzien zijn van zowel een **minimale (ZTA_min)**  als een **maximale (ZTA_max)**  waarde voor contactgeluidisolatie.\n\nDeze waarden vormen samen het bereik waarbinnen de akoestische prestatie van het bouwdeel wordt vastgelegd.\n",
    "Properties": [
      {
        "Name": "valueToValidate",
        "Value": {
          "Type": "sharedParameterSelector",
          "Properties": [
            {
              "Name": "guid",
              "Value": "fa4764bd-2046-4031-ab5e-d0a123c8004d",
              "Type": "string"
            }
          ]
        }
      },
      {
        "Name": "Validator",
        "Value": {
          "Type": "value",
          "Properties": [
            {
              "Name": "value",
              "Value": "string:ShouldNotBeEmpty",
              "Type": "string"
            }
          ]
        }
      },
      {
        "Name": "expectedValue",
        "Value": {
          "Type": "staticValueSelector",
          "Properties": [
            {
              "Name": "value",
              "Value": "not empty",
              "Type": "string"
            }
          ]
        }
      }
    ],
    "SubValidations": []
  },
  "Details": {
    "Name": "NLRS_C_ZTA_min >=0",
    "Impact": 4,
    "Priority": 3,
    "Tags": [
      "4.6 Bouwfysische eigenschappen"
    ],
    "Description": "",
    "HelpUrl": "https://help.daqs.io/NL/NLRS/NLRS_C_ZTA_min/?nav=false",
    "TimeToSolve": 5,
    "AllDisciplines": true,
    "Disciplines": []
  },
  "Metadata": [
    {
      "Label": "AssemblyCode",
      "Selector": {
        "Type": "querySelector",
        "Properties": [
          {
            "Name": "query",
            "Value": "values.assemblyCode",
            "Type": null
          }
        ]
      }
    }
  ]
}